Robe Spot 575 XT Specifications Page 26

  • Download
  • Add to my manuals
  • Print
  • Page
    / 31
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 25
26
Now you can calibrate the the colour, gobo and effect wheels by your controller. The DMX calibration protocol is
described in the table.
DMX Calibration protocol:
D
MX chanel
Fu
nction
1
Colour
Calibration 0-255
2
SGOB
Calibration 0-255
3
Effect
Calibration 0-255
4
Rotating gobo
Calibration 0-255
5
Gobo rotating
Calibration 0-255
6
No function
7
Colours
8
Static gobos
9
Effect
10
Prism rotation
11
Rotating gobos
12
Gobo rotation
13
Iris
14
Focus
15
Strobo
16
Dimmer
Standard protocol
Standard protocol
Standard protocol
Standard protocol
Standard protocol
Standard protocol
S
m
o
o
t
h
m
i
c
r
o
s
t
e
p
m
o
v
e
m
e
n
t
Standard protocol
Standard protocol
Standard protocol
Standard protocol
After having calibrated required functions press [Enter] to confirm (or [Menu] to cancel and return to the menu
without reset by the "ArES" function) and use the "ArES" function in order to write the calibration values to the
memory (EEPROM) and to make a reset in order to check the new adjusted positions of the colour,effect and
gobo wheels.
9. Error and information messages
HEAt
This message appears if you try to switch on the lamp within 5 minutes after having switched it off (the lamp is too
hot).The message will appear on the display if the lamp doesn't ignite within 28 seconds. The SCAN 575 XT will
store this information and automatically ignite the lamp when the 5 minutes period has expired.
Caution: The message is disabled if the lamp light sensor (function "En.Sn.") is switched Off (only if the lamp
was turned Off and On within 5 minutes,the message "
HEAt
" will appear).
LA.Er.
The ignition of the lamp is seven times unsuccessful (the "
HEAt
" message appeared six times before), and the
display shows "
LA.Er
", meaning that the lamp could be damaged or even missed, the fixture is overheating (this
can occur if the ambient temperature is 45° C or more) or there could be a failure on the ignitor or ballast.
Please place or replace the lamp, check the ambient temperature or contact your dealer if the situation was not
Page view 25