Manual control of effects
This function allows you to control manually the channel functions of the fixture. Use the [Up] and [Down] keys
to select desired function and press [Enter] to adjust the effect or [Mode] to cancel and return to the menu.
Lamp On automatically
This menu allows you to turn the lamp On after switching the fixture On and switch On/Off the lamp light sensor.
Lamp On after switching the fixture On
This function enables to turn the lamp On automatically after switching the fixture On. Use the
[Up] and [Down] keys to select "On" if you wish to turn the lamp On automatically after switching
the fixture On or "Off" if you wish the lamp Off after switching On the fixture and press [Enter] to
confirm or [Mode] to cancel and return to the menu.
Switch On/Off the lamp light sensor
Use the [Up] and [Down] keys to select "On" if you wish to switch the lamp light sensor On and
press [Enter] to confirm or [Mode] to cancel and return to the menu.The option"On" is for the
standard operation.
Use the [Up] and [Down] keys to select "Off" if you wish to switch the lamp light sensor Off and
press [Enter] to confirm or [Mode] to cancel and return to the menu.
Important: The option"Off" is for "emergency operation" only if the lamp light sensor is defective and
you will wait for a delivery of the spare light sensor! If the lamp light sensor was switched Off,the error
messages "LAEr,SnEr,HEAt" will not appear on the display (only the message "HEAt" will appear if the lamp
was turned Off and On within 5 minutes ) and at switching On of the lamp the electronics will still try to ignite the
lamp until it shines (even when the lamp is damaged or absent), on this account some electronics parts could be
damaged!